Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Language
Year range
1.
International Eye Science ; (12): 524-528, 2021.
Article in Chinese | WPRIM | ID: wpr-873458

ABSTRACT

@#AIM: To evaluate the long-term safety, efficacy and stability of posterior chamber intraocular lens(ICL)implantation for the correction of myopia.<p>METHODS: This retrospective non-randomized study included 107 eyes of 64 patients who were performed ICL implantation from January 2013 to December 2014. The uncorrected visual acuity, corrected visual acuity, intraocular pressure, the lens vault, endothelial cell morphometry were collected preoperatively and followed at 1wk, 1mo, 3mo, 6mo, 12mo and every year postoperatively.<p>RESULTS: The uncorrected visual acuity(LogMAR)was 0(-0.076, 0)at 1a postoperatively, and the uncorrected visual acuity 0.096(0, 0.221)decreased until last visit after the surgery. The change of visual acuity was associated with the change of axial length. The safety index was 1.19±0.24 and the efficacy index was 1.00±0.29 at the last visit postoperatively. The toric ICL implantation was stable without rotation at the last visit postoperatively. The vault of the ICL changed significantly in 1a postoperatively, but its change was smaller after 1a postoperatively. The intraocular pressure and endothelial cell morphometry did not changed significantly in long term postoperatively. Two eyes developed anterior cataract in 3a and 5a after the ICL implantation. There were no case developed pupillary block glaucoma.<p>CONCLUSION: Posterior chamber ICL implantation was a safe and stable procedure for the correction of myopia and astigmatism.

2.
International Eye Science ; (12): 1799-1802, 2017.
Article in Chinese | WPRIM | ID: wpr-641379

ABSTRACT

AIM:To evaluate the short-term efficacy of posterior chamber phakic intraocular lens implantation for moderate to high myopia.METHODS:Fifty-three eyes of 27 patients with moderate to high myopia (-3.25 to-21.5D) were received posterior chamber phakic intraocular lens implantation with 2.8mm clear corneal incision.Changes of visual acuity, intraocular pressure(IOP), counts of endothelial cells and surgically induced astigmatism at 1mo after surgery were observed.RESULTS:The preoperative best corrected visual acuity (BCVA LogMAR) were 0.05±0.18, the postoperative BCVA at 1d were 0.02±0.14, the postoperative BCVA at 1wk were-0.05±0.11, the postoperative BCVA at 1mo were-0.07±0.10.The postoperative BCVA were statistically significant differences in different time(P<0.05).The preoperative endothelial cell count was 2932.5±270.8/mm2, the postoperative endothelial cell count at 1d was 2917.1±299.0/mm2;the postoperative endothelial cell count at 1wk was 2902.5±288.6/mm2;the postoperative endothelial cell count at 1mo was 2855.3±284.2/mm2.The postoperative endothelial cell count was not statistically significant differences in different time.The preoperative IOP was 15.8±2.5mmHg;the postoperative IOP at 1d was 15.3±2.9mmHg;the postoperative IOP at 1wk was 17.4±5.8mmHg;the postoperative IOP at 1mo were 15.8±2.6mmHg.The preoperative IOP was significantly different compared with postoperative IOP at 1d, 1wk and 1mo.The postoperative IOP at 1d and 1wk were statistically significant differences (P<0.05).The surgically induced astigmatism at 1d was 0.74±0.39D;the surgically induced astigmatism at 1wk was 0.57±0.28D;the surgically induced astigmatism at 1mo was 0.44±0.21D.The postoperative IOP were statistically significant differences in different time (P<0.05).The preoperative anterior chamber depth was 3.26±0.25mm;the postoperative central vault at 1d were 654.5±345.2μm;the postoperative central vault at 1mo were 683.0±211.7μm.The postoperative central vault were significantly different between that at 1d and 1mo after operations.Operations went without serious complications.CONCLUSION:Posterior chamber phakic intraocular lens implantation for moderate to high myopia were safe, effective and predictability.But long-term effect remains needed to be further follow-up.

3.
Chinese Journal of Experimental Ophthalmology ; (12): 243-248, 2017.
Article in Chinese | WPRIM | ID: wpr-638190

ABSTRACT

Background With the development of refractive surgery,phakic intraocular lens implantation (PIOL) for high myopia is proving its outstanding merits in short-term treating outcomes.However,its long-term safety and effectiveness were still in more attention.Objective This study was to evaluate and compare the long-term safety,stability and efficacy of Verisyse PIOL implantation with implantable contact lens (ICL) implantation for high myopia.Methods The clinical data of 18 eyes (9 patients) who received Verisyse iris-claw intraocular lens implantation for high myopia and matched 22 eyes (11 patients) who received ICL implantation for high myopia from 2009 to 2011 were retrospectively analyzed.The patients were followed-up for 2 years after surgery.Uncorrected visual acuity (UCVA),best corrected visual acuity (BCVA),spherical equivalence (SE),axial length,corneal endothelial cell density (ECD),contrast sensitivity (CS),wave-front aberrations and postoperative complications were recorded during the following-up.The efficacy index,predictable and safety index were compared between the two groups.Results There was no significant difference in UCVA,BCVA and SE between Verisyse group and ICL group(t =0.92,1.32,4.32;all at P>0.05).Non-glare CS under the 1.5,3.0,6.0,12.0 and 18.0 c/d spatial frequencies were insignificantly different between the two groups(Z=0.782,0.956,0.495,0.874,0.293;all at P>0.05),and the similar outcomes were found in glare CS (Z=0.985,1.254,0.896,1.652,0.492;all at P>0.05) in postoperative 2 years.Root meas square of total high order aberration (RMSh),vertical-trefoil,vertical-coma,horizontal-coma,spherical aberration(SA),were significantly elevated in the Verisyse group compared with the ICL group (Z =4.72,4.24,3.12,3.65,2.16;all at P < 0.05).The mean efficacy index was 108.49 ± 16.62 in the V erisyse group and 106.71±15.88 in the ICL group,showing a significant difference (t =0.54,P>0.05).The mean safety index was 140.56±33.89 in the Verisyse group and 143.34±34.56 in the ICL group,with a significant difference between them (t=0.29,P>0.05).The mean predictable index was-0.25(-0.97,4.23)in the Verisyse group and 0.98 (-1.44,1.52) in the ICL group,and the difference was significant (Z =-2.68,P < 0.05).Conclusions Both Verisyse PIOL implantation and ICL implantation for high myopia are safe,predictable and effective.The vusial quality and predictability of ICL implantation are much better than Verisyse PIOL implantation.A long-term effect should be observed for the further evaluation.

4.
International Eye Science ; (12): 1319-1321, 2014.
Article in Chinese | WPRIM | ID: wpr-641989

ABSTRACT

AlM: To evaluate the clinical effect of implantation of phakic anterior chamber iris clip intraocular lens in high myopia patients. METHODS: Fifty eyes of 28 high myopia patients with anterior chamber phakic Verisyse iris clip intraocular lens implantation were observed. The visual acuity, best corrected visual acuity, intraocular pressure, corneal and anterior chamber inflammation changes were observed after the procedure. RESULTS: Fifty eyes of 28 high myopia patients were successfully accepted implantation of phakic anterior chamber iris clip intraocular lens. Visual acuity of all the patients was increased after operation. And one year later, visual acuity of 38 eyes ( 76%) ≥1. 0, 12 eyes (24%) ≥0. 5, best corrected visual acuity of 40 eyes (80%) ≥1. 0, 10 eyes ( 20%) ≥0. 5. ln 22 eyes, the postoperative best corrected visual acuity were reached and exceeded preoperative best corrected visual acuity.CONCLUSlON: lmplantation of iris clip intraocular lens in high myopia patients with anterior chamber lens was feasibility and effective.

5.
Chinese Journal of Experimental Ophthalmology ; (12): 926-930, 2011.
Article in Chinese | WPRIM | ID: wpr-635716

ABSTRACT

Background Implantation of phakic posterior chamber intraocular corrective lens(ICL)is a new choice for correction of high myopia.Different from laser assisted in situ keratomileusis,implantation of phakic posterior chamber ICL will allow the good imaging quality because it remaines the matched relationship between cornea and lens.But its visual quality after operation is concerned by patient and ophthalmologists.ObjectiveThis study was to observe the effectiveness of implantation of posterior chamber phakic ICL on visual quality in patients with high myopia.Methods Eighty-four high myopia eyes of 42 patients accepted implantation of posterior chamber phakic ICL and follow-up of 6-month duration.The visual acuity,refractive status,wavefront,contrast sensitivity and accommodation were examined and compared before and after surgery.This clinical study complied with Declaration of Helsinki.The written informed consent was obtained from each patient before operation.Results A prospective observational trial design was used.The uncorrected visual acuity and best corrected visual acuity after operation were better than preoperative ones in all of the patients.The eye numbers of > 0.3 were increased after operation in comparison with before operation with a stable result among 1 day,1 month and 6 months after surgery (x2 =10.70,P>0.05).Spherical equivalent refraction was(-15.38 ± 1.03)D before surgery and(+0.55 ±0.06)at 1 day,(-1.22±0.09)D at 1 month and(-0.68 ± 0.06)D after 6 months,showing a significant difference among them(F=16 559.90,P<0.05).Total aberrations and higher-order aberrations were 11.00±0.25 and 0.43 ±0.05 before surgery,the wavefront aberrations were 2.21 ± 0.56 and 0.47±0.04 at 6 months after surgery with significant difference(t =1.65,P =0.10).Each spatial frequency contrast sensitivity and glare sensitivity on photopic and seotopie conditions in postoperation were higher compared with the preoperative(P<0.05).The accommodation in 1 month and 6 months after surgery was greater than that of preoperative in the patients <-16 D(preoperation:2.75 ± 1.20 ; postoperation 1 month:5.75 ± 1.44,postoperation 6 months:6.00 ± 1.52)(P< 0.05),however,in the >-16 D group,no considerably change in accommodation was seen after surgery(F=1597.70,P<0.05).No significant difference was found in accommodation between before and after surgery in >-16 D group(F=2.67,P>0.05).Conclusions Visual quality of high myopia is obviously improved after implantation of posterior chamber phakic ICL,but its long-term outcome is need to further study.

6.
Chinese Journal of Experimental Ophthalmology ; (12): 423-426, 2011.
Article in Chinese | WPRIM | ID: wpr-635511

ABSTRACT

Background High myopia can be corrected using laser therapy and intraocular lens(IOL)implantation.IOL implantation is more suitable than laser therapy for high myopia if the patients suffer from thinner cornea.Objective This clinical trail was to assess and compare the visual quality following phakic iris-claw intraocular lens (IOL) and implantable contact lens(ICL) implantation for high myopia.MethodsIris-claw phakic intraocular lens was implanted in 17 eyes of 10 patients with high myopia,and age-,refractive-matched 17 eyes of 9 patients were in implantable contact lens (ICL) implantation group.Uncorrected visual acuity,best correct visual acuity,contrast sensitivity under the 3,6,12 and 18 c/d spatial frequencies,wave-front aberrations,including RMS3,RMS4 and RMSh,were examined in 6 months after operation.Written informed consent was obtained from each patient before surgery.Results There were no significant difference in uncorrected visual acuity,best correct visual acuity between two groups(t=0.489,P>0.05;t=0.853,P>0.05).Non-glare CS under the 3 c/d,6 c/d,12 c/d and 18 c/d spatial frequencies were insignificantly different between two groups ( t = 0. 906, P > 0.05 ; t = 0. 103, P > 0. 05 ; t =0. 694 ,P>0. 05 ; t = 1. 583, P>0. 05), and the similar outcomes were found in glare CS ( t = 0. 323, P>0.05, t =0.041 ,P>0. 05, t = 0.024, P>0. 05; t = 0. 363, P>0.05) in postoperative 6 months. RMS3 and RMSh were significantly elevated in PIOL group compared with ICL group ( t = 11.40, P0. 05). Conclusion Both PIOL and ICL implantation for high myopia can achieve an equal visual acuity. But clinical outcomes of ICL implantation is much better than PIOL group. A long-term effect should be observed for the further evaluation.

7.
Journal of Medical Research ; (12)2006.
Article in Chinese | WPRIM | ID: wpr-566254

ABSTRACT

Objective To evaluate the effeciency and safety of the implantation of phakic iris-fixated intraocular lens for high myopia.Methods 12 cases(18 eyes)with the mean spherieal equivalent refraction was(-15.12?5.23)diopters of myopia,following up 3~6 months after surgery(averaging 5.1 months)were enrolled.Visual acuity,intraocular pressure,contrast sensitivity,glare sensitivity,corneal endothelium and the stable of intraocular lens and the turbid level of lens were observed.Results A postoperation uncorrected visual acuity of(0.73?0.21)was observed in 18 eyes at 6 months.There was significant difference as compared with preoperation corrected visual acuity of(0.52?0.17)(P

8.
Journal of Medical Postgraduates ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-594235

ABSTRACT

Objective:Iris-fixed IOL implantation is a new and effective therapy for phakic eyes. Because the patients are young,they know very few about the operation,which mandated delicate pre-and postoperative nursing. This article discussed how to nurse the patients receiving iris-fixed IOL implantation operation in phakic eyes for super high myopia. Methods:Fifty eight eyes of 30 patients with super-high myopia received iris-fixed IOL (Verisyse IOL) implantation. Pre-and postoperative nursing course were summarized. Results:Focused education through preoperative visits,active cooperation in the operation and meticulous postoperative nursery were beneficial for the operation. Significant vision improvement was found after surgery. Conclusion:The planned,step by step,focused nursing course can improve the effects of operation and reduce the postoperative complication.

SELECTION OF CITATIONS
SEARCH DETAIL